Electrical Specifications

Basic Specifications

All specifications taken at 12V input and 25C ambient temperature unless stated otherwise.

Abbreviation

Parameter

Test Condition

Min

Typical

Max

Unit

Vin

Input Voltage

No load

5.3

16

V

Vout

Output Voltage

0 to 5A load

5.0

5.2

5.4

V

Tamb

Ambient Temperature Range

-20

40

°C

Icont

Continuous Current Output

4

A

Itrans

Transient Current Output

For 3 minutes

5

A

Imax

Peak Current Output

For 30 seconds

8

A

Other Specifications

Abbreviation

Parameter

Test Condition

Min

Typical

Max

Unit

Vsurge

Input Surge Voltage

For 5 seconds

24

V

Vdrop

Vin - Vout (Dropout)

No load

0.3

V

Vdrop

Vin - Vout (Dropout)

4A load

0.7

V

Lr

Load Regulation

0.01

V/A

Pfuse

Input Power Limit

36

W

η

Efficiency

1A load

96

%

η

Efficiency

4A load

92

%

Wiring Information

  • The input accepts wires between 16-24 AWG. Using wires outside this range may damage the connector or result in poor connections.

  • Ferrules can be used on wires between 18-24 AWG for improved connection reliability.

Protection Features

The Zinc-V includes built-in protection against short circuits and ESD events on the output.

In case of a short circuit, the Zinc-V will enter a powered-down sleep state until the device is power cycled.

There is a slow-blow resettable fuse on the input, which may have a lower trip current at elevated temperatures. Temporary overcurrent events, as would occur in 12V battery powered systems when the system voltage drops, will not trip the fuse. A chart of allowable continuous load current vs. ambient temperature, in still air, is shown below.

../_images/tempderate.jpg